SRX900 Series
SKU SRX912M
The SRX912M is an exceptionally compact, multi-purpose, two-way 12-inch powered point-source loudspeaker that delivers remarkably high output for its size.
| Overview | |
|---|---|
| |
| Specifications | |
| Size | 12" |
| Specifications | |
| Frequency Range (-10 dB) | 50 Hz - 20 kHz |
| Frequency Range (-3 dB) | 60 Hz - 19 kHz |
| Coverage Pattern | 90° x 60° |
| Rotatable Horn | No |
| Maximum SPL | 133 dB |
| System Type | Multi-purpose point-source, two-way powered |
| Amplifier Design | Class-D |
| Number of Channels | 2 |
| Continuous Power Rating | 600 Watts | LF: 400 Watts | HF: 200 Watts |
| Peak Power Rating | 880 Watts | LF: 580 Watts | HF: 300 Watts |
| Cooling | Convection, external aluminum heat sink, internal on-demand fan |
| LF Driver | (1) JBL 272F, 12 in, dual 2.0 in voice coil, ferrite Differential Drive® |
| HF Driver | (1) JBL 2408H-1, 1 in exit neodymium compression driver, 1.5 in voice coil |
| Input Type | Balanced line level |
| Input Connectors | (2) Neutrik XLR (IN/OUT) |
| Nominal Input Sensitivity | +1 dBu |
| Maximum Input Level | +21 dBu |
| Input Impedance | 100 kΩ |
| DSP Sample Rate | 48 kHz |
| DSP Bit Depth | 24 bit |
| System Latency | Main PA: 7.1 ms | Monitor: 2.9 ms |
| User Interface | LCD, encoder, Back button, (4) LED indicators (3 single, 1 bi-color) |
| Network Type | TCP/IP |
| Network Protocol | Harman HControl |
| Network Speed | Dual 100 Mbps ports |
| Network Connectors | (2) Neutrik etherCON |
| AC Voltage Range (Nominal) | 100-240 VAC, 50/60 Hz |
| AC Voltage Range (Limits) | 80-260 VAC, 50/60 Hz |
| AC Connectors | Dual (IN/OUT) Neutrik powerCON TRUE1 |
| Current Draw (Standby) | 100 V: 0.2 A | 120 V: 0.1 A | 208 V: 0.1 A | 240 V: 0.1 A |
| Current Draw (Idle) | 100 V: 0.3 A | 120 V: 0.3 A | 208 V: 0.2 A | 240 V: 0.2 A |
| Current Draw (Continuous) | 100 V: 1.7 A | 120 V: 1.4 A | 208 V: 0.9 A | 240 V: 0.8 A |
| Current Draw (Maximum Instantaneous Peak) | 100 V: 6.9 A | 120 V: 7.0 A | 208 V: 3.9 A | 240 V: 3.5 A |
| Current Draw (Peak Inrush) | 100 V: 1.8 A | 120 V: 2.1 A | 208 V: 3.7 A | 240 V: 4.4 A |
| Enclosure | Exterior grade birch plywood, DuraFlex finish, one integral handhold |
| Color | Black (RAL 9005) |
| Monitor Angle | 42° |
| Environmental Rating | IP54 (IEC 60529) | ASTM B117 | ASTM G155 |
| Suspension | (6) JBL QuickLink M10 points |
| Grille | Powder coated 1.5 mm (16 gauge) hex perforated steel with acoustically transparent black cloth backing |
| Dimensions (H x W x D) | 585mm x 380mm x 341mm (23.0 in x 15.0 in x 13.4 in) |
| Net Weight (each) | 20.6 kg (45 lbs) |
| Shipping Weight | 26.1 kg (58 lbs) |
| Optional Accessories | SRX912M UBV/UBH U-brackets, SRX900 RC2 rain cover, RC100 rotating clamp |
| Additional Specifications | |
| Configuration | 2-Way |
| Overview | |||
|---|---|---|---|
| |||
| Specifications | |||
| Size | 12" | ||
| Specifications | |||
| Frequency Range (-10 dB) | 50 Hz - 20 kHz | Network Type | TCP/IP |
| Frequency Range (-3 dB) | 60 Hz - 19 kHz | Network Protocol | Harman HControl |
| Coverage Pattern | 90° x 60° | Network Speed | Dual 100 Mbps ports |
| Rotatable Horn | No | Network Connectors | (2) Neutrik etherCON |
| Maximum SPL | 133 dB | AC Voltage Range (Nominal) | 100-240 VAC, 50/60 Hz |
| System Type | Multi-purpose point-source, two-way powered | AC Voltage Range (Limits) | 80-260 VAC, 50/60 Hz |
| Amplifier Design | Class-D | AC Connectors | Dual (IN/OUT) Neutrik powerCON TRUE1 |
| Number of Channels | 2 | Current Draw (Standby) | 100 V: 0.2 A | 120 V: 0.1 A | 208 V: 0.1 A | 240 V: 0.1 A |
| Continuous Power Rating | 600 Watts | LF: 400 Watts | HF: 200 Watts | Current Draw (Idle) | 100 V: 0.3 A | 120 V: 0.3 A | 208 V: 0.2 A | 240 V: 0.2 A |
| Peak Power Rating | 880 Watts | LF: 580 Watts | HF: 300 Watts | Current Draw (Continuous) | 100 V: 1.7 A | 120 V: 1.4 A | 208 V: 0.9 A | 240 V: 0.8 A |
| Cooling | Convection, external aluminum heat sink, internal on-demand fan | Current Draw (Maximum Instantaneous Peak) | 100 V: 6.9 A | 120 V: 7.0 A | 208 V: 3.9 A | 240 V: 3.5 A |
| LF Driver | (1) JBL 272F, 12 in, dual 2.0 in voice coil, ferrite Differential Drive® | Current Draw (Peak Inrush) | 100 V: 1.8 A | 120 V: 2.1 A | 208 V: 3.7 A | 240 V: 4.4 A |
| HF Driver | (1) JBL 2408H-1, 1 in exit neodymium compression driver, 1.5 in voice coil | Enclosure | Exterior grade birch plywood, DuraFlex finish, one integral handhold |
| Input Type | Balanced line level | Color | Black (RAL 9005) |
| Input Connectors | (2) Neutrik XLR (IN/OUT) | Monitor Angle | 42° |
| Nominal Input Sensitivity | +1 dBu | Environmental Rating | IP54 (IEC 60529) | ASTM B117 | ASTM G155 |
| Maximum Input Level | +21 dBu | Suspension | (6) JBL QuickLink M10 points |
| Input Impedance | 100 kΩ | Grille | Powder coated 1.5 mm (16 gauge) hex perforated steel with acoustically transparent black cloth backing |
| DSP Sample Rate | 48 kHz | Dimensions (H x W x D) | 585mm x 380mm x 341mm (23.0 in x 15.0 in x 13.4 in) |
| DSP Bit Depth | 24 bit | Net Weight (each) | 20.6 kg (45 lbs) |
| System Latency | Main PA: 7.1 ms | Monitor: 2.9 ms | Shipping Weight | 26.1 kg (58 lbs) |
| User Interface | LCD, encoder, Back button, (4) LED indicators (3 single, 1 bi-color) | Optional Accessories | SRX912M UBV/UBH U-brackets, SRX900 RC2 rain cover, RC100 rotating clamp |
| Additional Specifications | |||
| Configuration | 2-Way | ||
Questions about this speaker? Our pro audio team is here to help.